Code: C447, C449
Description: Heater temperature abnormality after abnormality judgment
Causes:
Remedy: 1 Power voltage Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) 2 Thermistor • Check if the center and edge thermistor are installed properly. • Check if the harnesses of the center and edge thermistor are open circuited. • Check if the connectors of the center and edge thermistor are disconnected (CN306, J608). 3 Switching regulator and fuser unit • Is the fuser unit installed correctly? • Check if the IH-COIL is broken. • Check if the terminal of the IH-COIL is attached securely. • Check if the thermostat is blown • Check if the drawer connector is damaged or its connection is detected. • Check if the connectors of the power supply unit are disconnected (CN504, CN505, CN56, CN564, CN565). • Check if the power supply unit is abnormal. 4 LGC board • Check if the connectors CN306 and CN302 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 5 Clear the status counter 1. Perform FS-08-2002. 2. Change the current status counter value "5", "6", "7", "9", "10", "22", "23", "24", "25", "27", "29", or "63 to 70". * The status counter value is as follows in the following cases. - The error occurred during warming-up: "5" or "6" The error occurred after the equipment has become ready: "7". - The temperature detected by the center thermistor is 220°C or higher, the temperature detected by the edge thermistor is 237°C or higher: "9", "10", "22", "23", "25", "27" or "29" - The error occurred during printing: "24", "25", or "64 to 70". - The error occurred during energy saving: "27". - A paper jam occurred: "29".