Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi EA60 — Toshiba e-Studio 4505AC

Code: EA60

Description: [MJ-1042] Early arrival jam [MJ-1109/1110] Early arrival jam
Causes: MJ-1109/1110 Feeding sensor (S22) Finisher controller PC board (FIN)
Remedy: MJ-1042 Entrance path sensor (S19) abnormality Measure the voltage on TP86 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V„b5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Finisher control PC board (FIN): CN22) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the sensor and the connector, exchange the finisher control PC board (FIN).
MJ-1109/1110 Paper Check if there is any paper in the finisher or on the transport path of the equipment and remove it if there is. Feeding sensor (S22) • Sensor check(S22) • Connector check (CN1) • Harness check Finisher controller PC board (FIN) • Board check • Connector check (CN1) • Harness check

← Xem tất cả mã lỗi Toshiba e-Studio 4505AC

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie