Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E920 — Toshiba e-Studio 4508A

Code: E920

Description: Stop jam at the bridge unit transport sensor-1: The trailing edge of the paper does not pass the bridge unit transport sensor-1 after its leading edge has reached the sensor.
Causes: Bridge unit transport sensor-1 (entrance sensor) LGC board Bridge unit gate solenoid
Remedy: There are scratches on the leading paper edge Replace it if needed.Check if the guide is not deformed. Replace it if needed. All Drawer Check that paper is not skewed in the side guides of the drawer. Bridge unit exit Check that Mylar on the bridge unit exit is not deformed. Replace it if needed. (E920) Finisher Check if paper jamming occurs in the finisher. Bridge unit transport sensor-1 (entrance sensor) • Sensor check (Perform the input check: FS-03- [ALL]OFF[0]/[A]) • Connector check (CN311, J607, J801) • Harness check Bridge unit gate solenoid • Solenoid check (Perform the output check: FS- 03-232) • Connector check (CN311, J607, J801) • Harness check LGC board • Board check • Connector check (CN311) • Harness check Bridge unit • Does the transport roller of the bridge unit work when the main motor is rotated? (Perform the output check: FS-03-101/151) • Check the drive system of the equipment and bridge unit. • Check if the rollers in exit section, bridge unit and pressure spring are worn out.