Description: Transport motor abnormality: The transport motor is not rotating normally.
Remedy: Is the transport motor working? (Perform the output check: 03-123/173) NO 1. Check if the connector J582 of the transport motor is disconnected. 2. Check if the connector CN348 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are opencircuited. 4. Check if the conductor patterns on the transport motor board and LGC board are short- or open-circuited. 5. Replace the transport motor. 6. Replace the LGC board. YES 1. Check if the PLL lock signal CN348-A7 pin output from the LGC board is always level “L”. 2. Check if the voltage supplied to the ASIC input terminal IC38-149 pin is always “L”. 3. Replace the LGC board.