Code: C130
Description: Upper drawer tray abnormality: The upper drawer tray motor is not rotating or the upper drawer tray is not moving normally.
Remedy: Does the tray go up? (Perform the output check: 03-242, 243) NO 1. Check if the connector of the tray-up motor is disconnected. 2. Check if the connector CN337 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open-circuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the LGC board. YES Is the tray-up sensor working? (Perform the input check: 03-[FAX]OFF/[6]/[H], /[6]/[G]) NO 1. Check if the connector of the sensor is disconnected. 2. Check if the connector CN337 on the LGC board is disconnected. 3. Check if the slit reaches the sensor. 4. Check if the connector pins are disconnected or the harnesses are open-circuited. 5. Check if the conductor pattern on the LGC board is short- or open-circuited. 6. Replace the LGC board. YES 1. Check if the conductor pattern on the LGC board is short- or open-circuited. 2. Replace the LGC board.