Code: C410
Description: Thermistor or heater abnormality at power-ON: Abnormality of service call the thermistor is detected when power is turned ON or the temperature of the fuser roller does not rise in a specified period of time after power is turned ON.
Remedy: 1. Check the thermistors (1) Check if the connectors are disconnected. (2) Check if the main, sub and front edge thermistors are in contact with the surface of the fuser belt properly? (3) Check if the harnesses of the main, sub and front edge thermistors are open-circuited. 2. Check the IH control board and IH coil (1) Check if the IH coil is broken. (2) Check if the connector of the IH coil is disconnected. (3) Check if the thermostats are blown. (4) Check if the connectors on the IH control board are disconnected (AC input connectors CN450, 451 and LGC I/F connectors CN455, 456). (5) Check if the IH control board or the switching power supply unit is abnormal. 3. Check the LGC board (1) Check if the connector CN358 is disconnected. (2) Check if the conductor pattern on the LGC board is short- or open-circuited. (3) Replace the LGC board. 4. Clear the status counter After repairing the matter which caused the error [C410], perform the following: (1) Turn ON the power while [0] and [8] are pressed simultaneously. (2) Key in “400”, then press the [START] button. (3) Change the current status counter value “1” or “2” to “0”, then press the [ENTER] button or [INTERRUPT] button (to cancel [C410]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.