Code: CCA0
Description: Lower stack tray lift motor abnormality: The lower stack tray lift motor is not rotating or the lower stack tray is not moving normally. [MJ-1022]
Remedy: MJ-1022 Is the wiring between the finisher controller PC board and lower stack tray lift motor (M7) correct? NO Correct the wiring. YES Are the front and rear sides of the lower stack tray leveled? NO Level them. YES Is the lower stack tray lift motor clock sensor (S9) working properly? NO Replace the sensor. YES Is the stack tray paper height sensor (S10) working properly? NO Replace the sensor. YES Are the lower stack tray upper limit sensor (S13) and lower stack tray full sensor (S23) working properly? NO Replace the sensor or sensor controller PC board. YES Does the voltage between the pins J3-1 and -2 on the finisher controller PC board become 24V when the lower stack tray lift motor starts rotating? NO Replace the finisher controller PC board. YES Check the wiring between the upper stack tray lift motor and finisher controller PC board. If there is no problem, replace the motor.