Code: CF30
Description: Reference plate detection voltage abnormality: The output value of the color auto-toner sensor against the reference plate is out of a specified range at the light amount correction during an auto-toner adjustment or when a print job has finished.
Remedy: Are the reference plate and color auto-toner sensor stained? YES Clean them. NO Is the color auto-toner sensor shutter solenoid working normally? (Perform the output check: 03-125/ 175) Is the color auto-toner sensor working? NO 1. Check if the connectors or joint connectors of the color auto-toner sensor shutter solenoid and color auto-toner sensor are disconnected. 2. Check if the connector CN356 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open-circuited. 4. Replace the color auto-toner sensor shutter solenoid. 5. Check if the conductor pattern on the LGC board is short- or open-circuited. 6. Replace the LGC board. 7. Replace the color auto-toner sensor and perform “Enforced correction of color auto-toner sensor light amount (05-208)”. YES Is the color auto-toner sensor shutter closing position correct? (Perform the output check: 03-125/175) NO Adjust the install position of solenoid so that the gap between the sensor holder and stopper will be 1.0 mm when closing the shutter. YES 1. Replace the LGC board. 2. Replace the reference plate and perform “Initialization of color auto-toner sensor light amount correction target value (05-207)”.