Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E480 — Toshiba e-Studio 4511

Code: E480

Description: Bridge unit open jam: The bridge unit has opened during printing.
Remedy: Is the Bridge unit open? YES Remove the paper if there is any, then close the unit. NO Is the bridge unit cover opening/closing detection switch working? (Perform the input check: 03-[FAX]ON/[0]/[B]) NO 1. Check if the connector of the bridge unit cover opening/closing detection switch is disconnected. 2. Check if the connector CN351 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open-circuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the bridge unit cover opening/closing detection switch. 6. Replace the LGC board. YES Replace the LGC board.