Code: E726
Description: Transport/exit signal reception jam: RADF receives the transport/exit reception signal from the equipment when no original is at the exposure waiting position.
Remedy: 1. If the original is remained in the RADF, remove it. 2. If any paper is remained in the copier, remove it. 3. Turn the power OFF and then back ON. If the jam still occurs, lead the following procedure. 4. Check the connection between the RADF board and SLG board, and the connection between the RADF board and switching power supply. - Are the connection of the connectors and joint connectors normal? - Are the connector pins disconnected or are the harnesses open-circuited? 5. Check if the 24V and 5V outputs of the switching power supply are normal. 6. Check if the conductor pattern on the RADF board is short- or open-circuited. 7. Replace the RADF board. 8. Check if the conductor pattern on the SLG board is short- or open-circuited. 9. Replace the SLG board.