Description: RADF open jam: RADF has opened during RADF operation.
Remedy: Is the RADF opened? YES Remove the original, if any, and close the RADF. NO Is the RADF opening/closing sensor adjusted within the specified range? NO Adjust the RADF opening/closing sensor. YES Is the RADF opening/closing sensor working? (Perform the input check: 03-[FAX]ON/[7]/[D]) NO 1. Check if the connector of the RADF opening/closing sensor is disconnected. 2. Check if the connector CN6 on the RADF board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open-circuited. 4. Check if the conductor pattern on the RADF board is short- or open-circuited. 5. Replace the RADF opening/closing sensor. 6. Replace the RADF board. YES Replace the RADF board.