Code: C270
Description: (1) Carriage home position sensor not turning OFF within a specified period of time: The carriage does not shift from its home position in a specified time.
(2) Downloading firmware with an incorrect model. If the error occurs, the exposure lamp lights twice at the same time.
(2) Downloading firmware with an incorrect model. If the error occurs, the exposure lamp lights twice at the same time.
Remedy: Are the carriages slightly moved to the feeding direction?/Are the carriages staying at a position other than home position? → YES → Check if the circuits of the SLG board are abnormal. NO 1) Check if the connector pin is disconnected or the harness is short circuited or open circuited. 2) Check if the conductor pattern on the SLG board is short circuited or open circuited. 3) Replace the SLG board.