Description: Micro switch abnormality: With all covers closed, inlet door switch, delivery door switch or front cover switch is open. [MJ-1024]
Remedy: MJ-1024 Are the front cover switch (MS31), inlet door switch (SW1) and delivery door switch (SW3) normal? → NO → Replace the switches. YES Measure the voltage between J704-1 (+) and J704-2 (-) on the finisher controller PC board. Is it 24V? → NO → Replace the finisher controller PC board. Is the wiring between J704 on the finisher controller PC board and J1 on the saddle stitcher controller PC board correct? → NO → Correct the wiring. YES Replace the saddle stitcher controller PC board.