Code: CE40

Description: Image quality control test pattern abnormality: The test pattern is not formed normally.
Remedy: (1) Use "Image quality control abnormal detection counter Y to K display/0 clearing (08-573 to 576)" to check the abnormal occurring condition for each color. (2) Check “Output value display of image quality sensor / Low-density pattern (05-391-0 to 3)” to check if the low-density pattern abnormality occurs for each color. The values under 320 for Y, M and C, and under 220 for K are defined as low-density pattern abnormality. Is the connectors CN338 on the LGC board disconnected? Is the connector of the image quality sensor disconnected or the surface of the sensor stained? Is the harness between the LGC board and the image quality sensor open circuited? Is the shutter of image quality sensor opening and closing normally? Is the shutter damaged? ↓→ YES→ <Procedure> 1) Take off the transfer belt unit so that the image quality sensor unit can be easily seen. 2) While pressing the digital keys [0] and [3] simultaneously, turn the power ON. 3) Key in “430”. 4) The shutter is opened and closed repeatedly by pressing the [START] button repeatedly. Connect the connector securely. Replace the harness. Clean the sensor. Replace the shutter if it is damaged. Replace the shutter solenoid if its operation is defective. NO Is the output voltage from the 12V-power supply normal? ↓→ NO → Check the power supply system, and replace the switching power supply. YES 1) Replace the image quality sensor. 2) Replace the LGC board. ↓→ 320 or above (Y, M and C) 220 or above (K) ↓→ Under 320 (Y, M and C) Under 220 (K) Low-density pattern abnormality Check the transfer belt. If the cleaning is poor, correct the transfer belt around its cleaning blade. ↓→ To (9) (3) Check “Output value display of image quality sensor / High-density pattern (05-390-0 to 3)” to check if the high-density pattern abnormality occurs for each color and identify the color which pattern is abnormal. If the value is 630 or above, it is defined as high-density pattern abnormality. (4) Set the values of “Image quality closed-loop control / Contrast voltage (08-556)” and “Image quality closed-loop control / Laser power (08-557)” to “0” (Invalid). (5) Perform “Enforced performing of image quality open-loop control (05-394)”. (6) Output the image quality control test pattern (04-270) more than one time and check the patch of the color identified in step (3) to see if the image is abnormal (Note). (7) Replace the image quality sensor. (8) Set the values of “Image quality closed-loop control / Contrast voltage (08-556)” and “Image quality closed-loop control / Laser power (08-557)” to “1” (Valid). (9) Perform “Enforced performing of image quality open-loop control (05-394)” and make sure it is completed normally. (Error [CE40] does not appear.) Then perform “Automatic gamma adjustment“ ( Chapter 3.5.1 and 3.6.1). (10) Clear all "Image quality control abnormal detection counter Y to K display/0 clearing (08-573 to 576)". Note: Abnormal image: Blank print, Solid print, White banding, Color banding, White spots, Poor transfer, Uneven image density, Faded image (low density), Uneven light distribution, Blotched image.

← Xem tất cả mã lỗi Toshiba e-Studio 451c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie