Code: EA10

Description: Paper transport delay jam: The paper which has passed the bridge unit does not reach the inlet sensor.[MJ-1031/1101] The paper which has passed the bridge unit does not reach the inlet sensor.
Remedy: MJ-1022 Is there any paper remaining on the transport path in the finisher or equipment? → YES → Remove the paper. NO Is the connector J10 on the finisher controller PC board disconnected? Is the harness connecting the finisher controller PC board and inlet sensor (S2) open circuited? → YES → Connect the connector securely. Replace the harness. NO Is the inlet sensor working normally? (Check the movement of the actuator.) ↓→ NO → 1) Connect the connector of the inlet sensor securely. 2) Attach the actuator securely if its shaft is out of place. 3) Replace the inlet sensor. YES Replace the finisher controller PC board.
MJ-1023/1024 Is there any paper remaining on the transport path in the finisher or equipment? → YES → Remove the paper. NO Is the connector J708 on the finisher controller PC board disconnected? Is the harness connecting the finisher controller PC board and inlet sensor (PI33) open circuited? → YES → Connect the connector securely. Replace the harness. NO Is the inlet sensor working properly? (Check the movement of the actuator.) ↓→ NO → 1) Connect the connector of the inlet sensor securely. 2) Attach the actuator securely if its shaft is out of place. 3) Replace the inlet sensor. YES Replace the finisher controller PC board.

← Xem tất cả mã lỗi Toshiba e-Studio 451c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie