Code: EA10
Description: Paper transport delay jam: The paper which has passed the bridge unit does not reach the inlet sensor.[MJ-1031/1101] The paper which has passed the bridge unit does not reach the inlet sensor. [MJ-1106]
Causes: MJ-1031 Finisher controller PC board Inlet sensor
MJ-1101 Entrance sensor Finisher controller PC board
MJ-1101 Entrance sensor Finisher controller PC board
Remedy: MJ-1031 Finisher controller PC board • Board check • Connector check (J104) • Harness check Inlet sensor • Sensor check • Is the inlet sensor working properly? (Check the movement of the actuator.)
MJ-1101 Entrance sensor Is there a disconnection of the connector, incorrect installation or breakage of the entrance sensor (S1)? Gate solenoid • Is the gap between the flapper and entrance roller shaft other than 0.60?0.20mm when the gate solenoid (SOL2) is pulled? • Is the harness between the gate solenoid (SOL2) and the finisher control PC board (CN22) disconnected or open circuited? Entrance motor Is the harness between the entrance motor (M1) and the finisher control PC board (CN7) disconnected or open circuited?
MJ-1101 Entrance sensor Is there a disconnection of the connector, incorrect installation or breakage of the entrance sensor (S1)? Gate solenoid • Is the gap between the flapper and entrance roller shaft other than 0.60?0.20mm when the gate solenoid (SOL2) is pulled? • Is the harness between the gate solenoid (SOL2) and the finisher control PC board (CN22) disconnected or open circuited? Entrance motor Is the harness between the entrance motor (M1) and the finisher control PC board (CN7) disconnected or open circuited?