Description: Micro switch abnormality: With all covers closed, inlet door switch, delivery door switch or front cover switch is open. [MJ-1024]
Remedy: MJ-1024 Are the front cover switch (MS31), inlet door switch (SW1) and delivery door switch (SW3) normal? NO Replace the switches. YES Measure the voltage between J704-1 (+) and J704-2 (-) on the finisher controller PC board. Is it 24 V? NO Replace the finisher controller PC board. YES Is the wiring between J704 on the finisher controller PC board and J1 on the saddle stitcher controller PC board correct? NO Correct the wiring. YES Replace the saddle stitcher controller PC board.