Description: RADF open jam: RADF has opened during RADF operation.
Remedy: Is the RADF opened? YES Remove the original, if any, and close the RADF. NO Is the RADF opening/closing sensor adjusted within the specified range? NO Adjust the RADF opening/closing sensor. YES Is the RADF opening/closing sensor working? (Perform the input check: 03-[FAX]ON/[7]/[D]) NO 1. Check if the connector of the RADF opening/closing sensor is disconnected. 2. Check if the connector CN6 on the RADF board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are opencircuited. 4. Check if the conductor pattern on the RADF board is short- or open-circuited. 5. Replace the RADF opening/closing sensor. 6. Replace the RADF board. YES Replace the RADF board.