Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CC60 — Toshiba e-Studio 455

Code: CC60

Description: Punch motor abnormality: The punch motor is not rotating normally or the puncher is not moving normally. [MJ-1025 (when MJ-6005 is installed)] Punch motor abnormality: Punch motor is not rotating or puncher is not shifting normally. [MJ-1024 (when MJ- 6004 is installed)]
Remedy: MJ-1025 (when MJ-6005 is installed) Is the punch home position sensor (PI1P) working properly? NO Replace the sensor. YES Is the punch motor clock sensor (PI3P) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and sensor correct? NO Correct the wiring. YES Is there any problem with the punching mechanism? YES Fix the mechanism. NO Replace Punch motor (M1P) Try replacing the punch controller PC board. Is the problem corrected? YES End. NO Replace the finisher controller PC board.
MJ-1024 (when MJ-6004 is installed) Are the punch home position sensor (PI63) and punch motor clock sensor (PI62) working normally? NO Replace the sensors. YES Is the wiring between the sensors and punch controller PC board correct? NO Correct the wiring. YES Is the punching mechanism normal? NO Fix the mechanism. YES 1. Replace the punch motor (M61). 2. Replace the punch controller PC board. 3. Replace the finisher controller PC board.