Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E510 — Toshiba e-Studio 455

Code: E510

Description: Jam not reaching the ADU entrance sensor: The paper does not reach the ADU entrance sensor after it is switchbacked in the exit section.
Remedy: Open the ADU. Is there any paper in front of the ADU exit sensor? YES Remove the paper. NO Is the ADU exit sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[1]/[E]) NO 1. Check if the connector of the ADU exit sensor is disconnected. 2. Check if the connector CN311 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor patterns on the LGC board are short circuited or open circuited. 5. Replace the ADU exit sensor. 6. Replace the LGC board. YES Is the ADU motor working? (Perform the output check in the test mode: 03-119) NO 1. Check if the connector of the ADU motor is disconnected. 2. Check if the connector CN402 and CN404 on the MOT/MOT2 board is disconnected. 3. Check if the connector CN303 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor pattern on the LGC board is short circuited or open circuited. 6. Replace the ADU exit sensor. 7. Replace the MOT/MOT2 board. 8. Replace the LGC board. YES Check the rollers in the ADU. Replace them if they are worn out