Code: E930
Description: Jam at the bridge unit transport sensor-2: The trailing edge of the paper does not reach the bridge unit transport sensor-2 after its leading edge has reached the bridge unit transport sensor-1.
Remedy: 1. Check if there is any paper in the bridge unit and remove it if there is. 2. Is the bridge unit transport sensor-2 working? (Perform the input check:03-[FAX]OFF/[5]/[D]) * If it is working properly, proceed to 6. If not, check 3 to 5 below. 3. Check if the connector CN334 on the LGC board is disconnected from the bridge unit transport sensor-2 (exit sensor) or the harnesses are open circuited. Check if the connector J523 of the bridge unit is disconnected. Correct if any. 4. Replace the bridge unit transport sensor-2. 5. Replace the LGC board. 6. Does the transport roller of the bridge unit work when the fuser motor is rotated? (Perform the output check: 03-113/163) * If it is working properly, proceed to 8. If not, check 7 below. 7. Check the drive system of the equipment and bridge unit. 8. Check if the rollers in the exit roller, the pressure spring and the bridge unit are worn out.