Code: EA60
Description: Early arrival jam: The inlet sensor detects the paper earlier than a specified timing
Remedy: MJ-1024 1. Check if there is any paper in the finisher or on the transport path of the equipment or on the stapling tray. Remove it if there is. 2. Check if the connector on the finisher controller PC board is disconnected from the inlet sensor (P133) or the harnesses are open circuited. Correct if any. 3. Check if the inlet sensor (P133) is working (or if the actuator returns) properly. 4. Replace the inlet sensor. 5. Replace the finisher controller PC board.
MJ-1031 1. Check if there is any paper in the finisher or on the transport path of the equipment and remove it if there is. 2. Check if the connector J104 on the finisher controller PC board is disconnected from the inlet sensor (SR2) or the harnesses are open circuited. Correct if any. 3. Is the inlet sensor working properly? (Check the movement of the actuator.) 4. Replace the inlet sensor. 5. Replace the finisher controller PC board.
MJ-1101 1. Check if there is any paper in the finisher or on the transport path of the equipment or on the finishing tray. Remove it if there is. 2. Check if there is any disconnection, incorrect installation or breakage on the entrance sensor (S1). Correct if any. 3. Check if the connector CN7 on the finisher controller PC board is disconnected from the entrance sensor (S1) and the harnesses are disconnected or open circuited. Correct if any. 4. Replace the entrance sensor. 5. Replace the finisher controller PC board.
MJ-1031 1. Check if there is any paper in the finisher or on the transport path of the equipment and remove it if there is. 2. Check if the connector J104 on the finisher controller PC board is disconnected from the inlet sensor (SR2) or the harnesses are open circuited. Correct if any. 3. Is the inlet sensor working properly? (Check the movement of the actuator.) 4. Replace the inlet sensor. 5. Replace the finisher controller PC board.
MJ-1101 1. Check if there is any paper in the finisher or on the transport path of the equipment or on the finishing tray. Remove it if there is. 2. Check if there is any disconnection, incorrect installation or breakage on the entrance sensor (S1). Correct if any. 3. Check if the connector CN7 on the finisher controller PC board is disconnected from the entrance sensor (S1) and the harnesses are disconnected or open circuited. Correct if any. 4. Replace the entrance sensor. 5. Replace the finisher controller PC board.