Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CC61 — Toshiba e-Studio 4555CSE

Code: CC61

Description: Punch motor abnormality [MJ-1036]Punch motor (M3) home position detection error: Punch motor is not rotating or puncher is not shifting normally. [MJ-1107/1108 (whenMJ-6104 is installed)]
Causes: MJ-1107/1108 (When MJ-6104 is installed) Punch home position sensor (S4) Punch motor (M3) Hole punch control PC board (HP)
Remedy: MJ-1036 Punch motor (M11) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Rear punch shaft home position sensor (S22) abnormality Measure the voltage on TP25 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Punch shaft home position sensor (S26) abnormality Measure the voltage on TP24 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Punch motor clock sensor (S20) abnormality Measure the voltage on TP27 on the hole punch control PC board (HP). Then check that the measured voltage is 1V or lower when not shielded and within the range of 5V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN2, CN5, CN6) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the motor, sensors and connectors, exchange the hole punch control PC board (HP).
MJ-1107/1108 (When MJ-6104 is installed) Transport path If there is any paper remaining on the transport path, remove the paper. Punch motor (M3) • If there is mechanical problem when the punch motor (M3) is rotated, fix the mechanism. • Check the connectors and harnesses between the hole punch control PC board (HP) and punch motor (M3). Punch home position sensor (S4) • Sensor check • Harness check

← Xem tất cả mã lỗi Toshiba e-Studio 4555CSE

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie