Remedy: SRAM Check the connection of SRAM 1. Turn the power OFF, and start up the Setting Mode (08). 2. When “SRAM REQUIRES INITIALIZATION” is displayed on the LCD, check the destination and then press the [START] button. If the destination is not correct, key in the correct one and then press the [START] button. (SRAM is initialized.) 3. After the confirmation message is displayed, press the [INTERRUPT] button. 4. Perform the panel calibration (08-9050). 5. Enter the serial number (08-9601). Match it with the serial number on the label attached to the rear cover of the equipment. 6. Initialize the NIC information (08-9083). 7. Turn the power OFF and then start up with the Adjustment mode (05). 8. Perform “Data transfer of characteristic value of scanner” (05-3203). 9. Perform “Automatic gamma adjustment” <PPC> (05-7869). (using [4][FAX] test pattern) 10.Perform “Automatic gamma adjustment” <PRT> (05-8008). (using [70][FAX] test pattern) 11.Turn the power OFF and then back ON. SYS board Board check