Mã lỗi CB40 — Toshiba e-Studio 456

Code: CB40

Description: Front alignment motor abnormality: The front alignment motor is not rotating or the front align/1106ment plate is not moving normally. [MJ-1101] Front alignment plate home position detection error: The detection of the home position ends abnormally because the front alignment plate has not worked properly. [MJ-1032/MJ-1033]
Causes: MJ-1101 Front alignment motor (M9) Finisher controller PC board
MJ-1106 Front alignment motor (M5) Finisher controller PC board
Remedy: MJ-1101 Front alignment plate If there is mechanical problem when the front alignment plate is moved, fix the mechanism. Front alignment motor (M9) Check the connectors and harnesses between the front alignment motor (M9) and the finisher control PC board (CN10).
MJ-1106 Front alignment plate If there is mechanical problem when the front alignment plate is moved, fix the mechanism. Front alignment motor (M5) Check the connectors and harnesses between the front alignment motor (M5) and the finisher control PC board (CN10).
MJ-1032 Rear alignment motor (M3) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Rear alignment plate home position sensor (S6) abnormality Measure the voltage on TP16 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN5, CN12) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensor and connectors, exchange the finisher control PC board (FIN).
MJ-1033 Rear alignment motor (M7) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Rear alignment plate home position sensor (S10) abnormality Measure the voltage on pin CN9.9 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN2, CN9) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensor and connectors, exchange the finisher control PC board (FIN)