Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CF10 — Toshiba e-Studio 456

Code: CF10

Description: Communication module SRAM reading failure. [MJ-1101]
Causes: MJ-1101 Converter PC board Finisher control PC board
MJ-1101 (When MJ-6103 is installed) Converter PC board Finisher control PC board Hole punch control PC board
Remedy: MJ-1101 Main power switch Turn OFF the main power switch, then back ON. Setting of the equipment Check if the MJ-1101 is set as the specified finisher on the equipment. (08-4548) Converter PC board • Check the connectors and harnesses between the converter PC board and the finisher controller PC board. • Board check Finisher control PC board Board check
MJ-1101 (When MJ-6103 is installed) Setting of the equipment Check if the MJ-1101 is set as the specified finisher on the equipment. (08-4548) Converter PC board • Check the connectors and harnesses between the converter PC board and the finisher controller PC board. • Board check Finisher control PC board • Check the connectors and harnesses between the hole punch control PC board and the finisher control PC board. • Board check Hole punch control PC board Board check

← Xem tất cả mã lỗi Toshiba e-Studio 456