Remedy: 1 Checking of paper • Open the ADU and remove paper if there is any on the transport path. * If the error still occurs, check the following: 2 2 Is the reverse sensor working? (Perform the input check in the test mode: 03-[FAX]ON/[9]/[C]) Yes 3 No - Check if the connector pins are disconnected or the harnesses are open circuited between the reverse sensor and the connector CN304 on the LGC board. Correct if there is any abnormality. - Replace the reverse sensor. - Replace the LGC board. 3 Is the reverse motor working? (Perform the output check in the test mode: 03-123/173) Yes Check the exit roller. Replace it if it is worn out. No • Check if the connector pins are disconnected or the harnesses are open circuited between the reverse motor and the connector CN304 on the LGC board (and also the connectors CN401 and CN406 on the MOT2 board). Correct if there is any abnormality. • Replace the reverse motor. • Replace the MOT2 board. • Replace the LGC board.