Mã lỗi EA32 — Toshiba e-Studio 456

Code: EA32

Description: Exit paper remaining jam. [MJ-1101/MJ-1106] Exit paper remaining jam in the Finisher: Paper is detected in the finishing tray sensor when the power is turned ON. [MJ-1032/MJ-1033]
Causes: MJ-1101 Processing tray sensor Finisher controller PC board
MJ-1106 Processing tray sensor (S12) Finisher control PC board (FIN)
Remedy: MJ-1101 Processing tray sensor • Sensor check (S12) • Connector check (CN11) • Harness check Finisher controller PC board • Sensor check • Connector check (CN11) • Harness check
MJ-1106 Finisher Check if there is any paper in the finisher or on the transport path of the equipment and remove it if there is. Processing tray sensor (S12) • Sensor check • Connector check • Harness check Finisher control PC board (FIN) • Board check • Connector check (CN18) • Harness check
MJ-1032 Finishing tray sensor (S4) abnormality Measure the voltage on TP14 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Finisher control PC board (FIN): CN5) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the sensor and the connector, exchange the finisher control PC board (FIN).
MJ-1033 Finishing tray sensor (S2) abnormality Measure the voltage on TP26 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Finisher control PC board (FIN): CN8) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the sensor and the connector, exchange the finisher control PC board (FIN).