Code: ED14
Description: Rear alignment plate home position error: The rear alignment plate is not at the home position. [MJ- 1101/MJ-1106]
Causes: MJ-1101 Front alignment motor Front alignment plate home position sensor Finisher controller PC board
MJ-1106 Rear alignment plate home position sensor Finisher controller PC board
MJ-1106 Rear alignment plate home position sensor Finisher controller PC board
Remedy: MJ-1101 Rear alignment plate Move the Rear alignment plate. If there is any mechanical problem, fix its mechanism. Rear alignment motor Rear alignment plate home position sensor Finisher controller PC board Check if the connectors on the finisher controller PC board are disconnected from the Rear alignment plate home position sensor (S8) and the Rear alignment motor (M10), or the harnesses are open circuited. Correct if any.
MJ-1106 Rear alignment plate Move the rear alignment plate. Fix any mechanical problem. Rear alignment plate home position sensor Check if there is a disconnection of the connector, incorrect installation or breakage of the rear alignment plate home position sensor (S8). If there is, reinstall the sensor correctly or replace it. Check if the connector (CN18) on the finisher controller PC board is disconnected from the rear alignment plate home position sensor (S8) and the harnesses are open circuited. Correct if so. Rear alignment motor Check if the connector (CN17) on the finisher controller PC board is disconnected from the rear alignment motor (M6) and the harnesses are open circuited. Correct if so.
MJ-1106 Rear alignment plate Move the rear alignment plate. Fix any mechanical problem. Rear alignment plate home position sensor Check if there is a disconnection of the connector, incorrect installation or breakage of the rear alignment plate home position sensor (S8). If there is, reinstall the sensor correctly or replace it. Check if the connector (CN18) on the finisher controller PC board is disconnected from the rear alignment plate home position sensor (S8) and the harnesses are open circuited. Correct if so. Rear alignment motor Check if the connector (CN17) on the finisher controller PC board is disconnected from the rear alignment motor (M6) and the harnesses are open circuited. Correct if so.