Code: CC92
Description: The movable tray exceeds its upper limit.
Causes:
Remedy: Movable tray shift motor (M5) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Movable tray shift motor clock sensor (S15) abnormality Measure the voltage on pin CN7.3 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Movable tray upper limit sensor (S16) abnormality Measure the voltage on TP35 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Movable tray lower limit sensor (S17) abnormality Measure the voltage on TP28 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Movable tray middle sensor (S18) abnormality Measure the voltage on TP29 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor.