Mã lỗi C180 — Toshiba e-Studio 457S

Code: C180

Description: LCF tray-up motor abnormality: The LCF tray-up motor is not rotating or the LCF tray is not moving normally.
Causes: LCF board LGC board LCF tray-up moto LCF tray-up sensor
Remedy: 1 Does the tray move? (Perform the output check in the test mode: 03-271) Yes 2 No 1. Does the tray move? (Perform the output check in the test mode: 03-271) 2. Check if the connector of the LCF tray-up motor is disconnected. 3. Check if any of the connectors CN1 and CN5 on the LCF board is disconnected. 4. Check if the connector CN318 on the LGC board is disconnected. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 7. Replace the LCF board. 2 Are the LCF tray bottom sensor and LCF tray-up sensor working? (Perform the input check in the test mode: 03- [FAX]OFF/[5]/[A], /[5]/[B]) Yes 3 No 1. Check if the connectors of the sensors are disconnected. 2. Check if any of the connectors CN1, CN2 and CN6 on the LCF board is disconnected. 3. Check if the connector CN318 on the LGC board is disconnected. 4. Check if the slit reaches the sensors. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 7. Replace the LCF board. 8. Replace the LGC board. 3 LGC board 1. Check if the conductor pattern on the LGC board is short circuited or open circuited. 2. Replace the LGC board.

← Xem tất cả mã lỗi Toshiba e-Studio 457S

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie