Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E910 — Toshiba e-Studio 457S

Code: E910

Description: Jam at the bridge unit transport sensor-1: The paper does not reach the bridge unit transport sensor-1 after it has passed the exit sensor.
Causes: Bridge unit transport sensor-1 LGC board Bridge unit gate solenoid
Remedy: 1 Bridge unit Check if there is any paper in the bridge unit and remove it if there is. 2 2 Is the bridge unit transport sensor-1 working? (Perform the input check : 03-[FAX]OFF/[3]/[F]) / 03- [FAX]OFF/[4]/[F]) Yes 3 No 1. Check if the connector CN302 on the LGC board is disconnected from the bridge unit transport sensor-1 (entrance sensor) or the harnesses are open circuited. Check if the connector J681 of the bridge unit is disconnected. Correct if any. 2. Replace the bridge unit transport sensor-1. 3. Replace the LGC board. 3 Is the bridge unit gate solenoid working? (Perform the output check: 03-232) Yes 4 No 1. Check if the connector CN302 on the LGC board is disconnected from the bridge unit gate solenoid or the harnesses are open circuited. Check if the connector J681 of the bridge unit is disconnected. Correct if any. 2. Replace the bridge unit gate solenoid. 3. Replace the LGC board. 4 Does the transport roller of the bridge unit work when the fuser motor is rotated? (Perform the output check: 03-113/163) Yes Check if the rollers in the exit roller, the pressure spring and the bridge unit are worn out. No Check the drive system of the equipment and bridge unit.

← Xem tất cả mã lỗi Toshiba e-Studio 457S

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie