Mã lỗi F109_0 — Toshiba e-Studio 457S

Code: F109_0

Description: Key consistency error: Consistency check operation error.
Causes:
Remedy: Setting Reboot the equipment. If it cannot be recovered, reinstall the software in the following procedure. (1) Install the OS data. "11.2.1 Master data/System ROM/Engine ROM/Scanner ROM / RADF ROM" (2) Reinstall the master data and application program. "9.2.3 Precautions and procedures when replacing the HDD" [E] Replace / Format HDD (Step (3) and later in [E] Replace / Format HDD)" SRAM board (1) If the error is not cleared even after reinstallation, replace the SRAM board. "9.2.8 Precautions and Procedures when replacing SRAM board" (2) If the error is not cleared even after replacing the SRAM board, replace the SYS board. "9.2.4 Precautions and Procedures when replacing the SYS board"