Code: CE41
Description: The image quality TRC control test pattern is not printed normally
Causes: LGC board SYS board High-voltage transformer
Remedy: 1 Change the setting of the image quality TRC control to "Disabled". Set the values of FS-08-2600 and FS-08- 8103 to "0". 2 2 Output several number of sheets of the image quality control test pattern (FS-04- 270) and the list print (FS- 30-101), and check the pattern of each color. Is the image normal? YES 3 NO ¡E Check if process units and developer units are properly installed. ¡E Check if there is any scattered toner or developer material around the laser optical unit, clean it if there is any. ¡E Correct the problem by referring to "Troubleshooting for the Image". ƒt P. 8-312 "8.5 Troubleshooting for the Image" 3 Change the setting of the image quality TRC control to "Enabled". Set the values of FS-08-2600 and FS-08- 8103 to "1". 4 4 Perform the automatic gamma adjustment. If the adjustment is normally finished, this is the end of the procedure. If the error CE41 still occurs, proceed to step 5. 5 4.Check if the harness between the connector CN131 on the SYS board and the connector CN330 on the LGC board is disconnected or open circuited. Correct if so. 6 6 6.Check if the conductor patterns on the SYS board and the LGC board are short circuited or open circuited. 7 7 7.If no abnormality is found in steps 5 to 6 above, replace the SYS board. 8 8.Perform automatic gamma adjustment. If the adjustment is normally finished, this is the end of the procedure. If the error CE41 still occurs, proceed to step 9. 9 Reinstall the removed SYS board and then replace the LGC board. Perform automatic gamma adjustment after the board is replaced.