Mã lỗi CB51 — Toshiba e-Studio 5008A

Code: CB51

Description: Staple unit sliding motor (M7) abnormality MJ-1042
Causes: Staple unit sliding motor (M7) Staple unit sliding home position sensor (S3) The turning OFF of the staple unit sliding home position sensor (S3) is not detected when the staple unit is moved from a point where this sensor is turned ON to one point where this sensor is turned OFF after the staple unit sliding motor (M7) has been driven at the specified number of pulse. The turning ON of the staple unit sliding home position sensor (S3) is not detected when the staple unit is moved from a point where this sensor is turned OFF to one point where this sensor is turned ON after the staple unit sliding motor (M7) has been driven at the specified number of pulse.
Remedy: Staple unit sliding motor (M7) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the staple unit. Staple unit sliding home position sensor (S3) abnormality Measure the voltage on TP18 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3„b5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN3, CN18) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the staple unit, sensors and connectors, exchange the finisher control PC board (FIN).

← Xem tất cả mã lỗi Toshiba e-Studio 5008A

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie