Mã lỗi ED11 — Toshiba e-Studio 5008A

Code: ED11

Description: Sideways adjustment motor (M2) home position detection error: The Sideways adjustment motor is not at the home position. [MJ-1109/1110 (MJ-6105)]
Causes: Sideways adjustment motor (M2) Sideways deviation HP sensor (S3) Hole punch control PC board (HP)
Remedy: Paper • Check if there is any paper in the hole punch unit, finisher or the on the transport path of the equipment. Remove it if there is. • Use paper accepted in the specifications. Sideways adjustment motor (M2) Rotate sideways adjustment motor and fix its mechanism if it does not rotate smoothly. Sideways deviation HP sensor (S3) Sideways adjustment motor (M2) Hole punch control PC board (HP) Check if the connectors on the hole punch controller PC board (HP board) are disconnected from the sideways deviation HP sensor (S3) and the sideways adjustment motor, or the harnesses are open circuited. Correct if any.