Code: 927.00
Description: Service fan error.
Causes: • Loose connector. • External blockage of the fan, preventing it from turning. • Bad fan.
Remedy: 1 Main fan Check the main fan to make sure it is plugged into J4 on the system board. If the fan cable id correctly connected to J4, check the cable and the cable connector for any signs of damage. If damaged, replace the main fan assembly. See “Main fan removal”1. If undamaged, go to step 2. 2 Main fan Turn the printer off and check the main fan for any signs of blockage of the fan blades. If there is any sign of blockage, remove the blockage. 3 Main fan blades turn during POR, then stop. Fan will not run when trying to print. Main fan System board Measure the voltage at J4-1 on the system board. The voltage should measure approximately +2.5 V dc. If incorrect, replace the main fan. See “Main fan removal”1. If that does not fix the problem, replace the system board. See “System board and inner shield removal —model 500S"1. 4 Main fan blades do not turn Measure the voltage at J4-3. The voltage should measure +14.4 V dc with the fan running full and approximately 7.0 V dc when running half speed. If incorrect, replace the main fan. See “Main fan removal”1. If this does not fix the problem, replace the system board. See “System board and inner shield removal — model 500S”1.