Mã lỗi CE20 — Toshiba e-Studio 5055C

Code: CE20

Description: Image quality sensor abnormality (no pattern level): The output value of this sensor is out of a specified range when the image quality control test pattern is not formed.
Causes:
Remedy: • Check the image quality sensor detection value (05-2757). • Is the value of 05-2757-0 "0", and is the value of 05-2757-1 "255"? Yes 9 No 2 2 • Is the transfer belt or the transfer belt unit securely installed? • Are there any abnormal stains (cleaning defects), large scratches or breaking on the transfer belt surface? • Are the drum and the transfer belt rotating smoothly? • Is the transfer belt tight? Yes 6 No 3 3 Transfer belt unit Check if the transfer belt unit is securely installed. Correct it if not. 4 4 Transfer belt Check if any toner image remains on the transfer belt surface. If any, check the installation status of the TBU cleaner unit. If there is any abnormality, correct it, and clean the transfer belt. 5 5 Drum and transfer belt Check if the drum and the transfer belt are properly operated. (ON: 03-101 / OFF: 03-151) If the transfer belt rotates normally, check if any abnormal stains (cleaning defects), large scratches or breaking are on the surface of transfer belt by making full rotation of transfer belt. Replace the transfer belt if any. Check if the transfer belt is loose or heaving, and correct it if needed. If they are not rotating normally, check if their drive gears are damaged or if they contact the equipment. Correct it if needed. 19* 6 • Is the sensor shutter of the image quality sensor opening or closing normally? Or is it normal without any damage? • Is the sensor surface of the image quality sensor clean? Yes 9 No 7 7 Sensor unit Take off the transfer belt unit so that you can see the sensor unit. 8 Sensor shutter • Check if the sensor shutter is opening or closing normally. (Opening: 03-125 / Closing: 03- 175) If the sensor shutter is not opening or closing, check if it is damaged or there is any abnormality in the sensor shutter solenoid. * If the shutter is opened (03-125), close the shutter (03-175). • Check the connector and the harness between the sensor shutter solenoid and the LGC board. (LGC CN337-8pin, 9pin) • Slide the sensor shutter so that the sensor surface can be seen. Clean the sensor surface with a cotton swab or a soft cloth. Clean the area around the sensor (e.g.: sensor shutter) if it is stained, so that the sensor surface does not become dirty. 9 Image quality sensor Check the connectors and harnesses between the LGC board (CN366) and the image quality sensor. * 10 • Is +5V power supply voltage normally supplied to the image quality sensor? • Is +5V voltage normally output by the CN345-7pin on the LGC board? Yes 13 No 11 11 Switching power supply Check if +5V voltage is output by the switching power supply (PS-ACC CN404-7pin). 12 LGC board • Check if +5V voltage is output by the C33 + terminal on the LGC board. • Check if the supply harness between the switching power supply and the LGC board is open circuited, damaged or disconnected. 19* 13 Set the values of "Image quality closed-loop control / Contrast voltage (08-2486)" to "0" (Invalid). 14 Perform “Enforced performing of image quality open-loop control (05-2740)”. 15 Output the image quality control test pattern (04-270) more than one time and the list print ([9][START]). Is the image normal? Yes 17 No 16 16 Abnormal image Correct the abnormal image. Blank print, Solid print, White banding, Color banding, White spots, Poor transfer, Uneven image density, Faded image (low density), Uneven light distribution, Blotched image. * Blank print: including when one of the YMCK colors is not printed. 18 17 Replace the image quality sensor or the LGC board. 18 Set the values of “Image quality closed-loop control / Contrast voltage (08-2486)” to “1” (Valid). 19 Perform "Forced performing of image quality closed-loop control (05-2742)" and make sure it is completed normally. (Error [CE10], [CE20] and [CE40] do not appear.) Yes 21 No 20 20 Check and correct it accordingly. 21 Perform "Automatic gamma adjustment". 22 Reset all of the values in the codes “Abnormality detection count (Y/M/ C/K) Display/0 clearing (08-2528 to 08-2531)”.

← Xem tất cả mã lỗi Toshiba e-Studio 5055C

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie