Mã lỗi F070 — Toshiba e-Studio 5055C

Code: F070

Description: Communication error between System-CPUand Engine-CPU
Causes: LGC board SYS board LED head HRNS-LGC-DEV-212 HRNS-LGC-DRM-212 HRNS-LGC-ADU-212 HRNS-DRV-SFBTRU-212
Remedy: Error code • Turn the power OFF and then back ON using the main power switch, and then check if the error code changes to another one. • If it changes to another one, follow the procedure for the changed error code. Check firmware version • Check the version of the system firmware on the SYS board. • Check the version of the engine firmware on the LGC board. Board check • Check if the connector CN128 on the SYS board and the connector CN350 on the LGC board are completely inserted. • Check if the connector pin between the SYS board (connector CN128) and the LGC board (connector CN350) is disconnected. • Check if the connectors CN380, CN381, CN382, CN383, CN384, CN385, CN386 and CN387 of the LED head are completely inserted, and the harness is disconnected or open circuited. • Check if the conductor patterns on the LGC board and SYS board are short circuited or open circuited HRNS-LGC-DEV-212 HRNS-LGC-DRM-212 HRNS-LGC-ADU-212 HRNS-DRV-SFBTRU-212 • Connector check • Harness check