Mã lỗi C3D1 — Toshiba e-Studio 506

Code: C3D1

Description: Process related service call EPU board memory new parts detection error: The EPU board detects the process unit as a new unit when the equipment is started in the normal mode.
Causes: EPU memory board LGC board
Remedy: Process unit 1. If the process unit has been replaced with a new one before the equipment is started, turn the power OFF and then back ON in the EPU replacement mode ([7] + [START]). 2. If the process unit has not been replaced, check the following. 3. Check if the process unit is properly installed, and check if the connector pins that are connected to the equipment are disconnected or have any abnormality such as deformation. 4. Check if the harness connected to the connector J451 on the EPU board has any abnormality.