Code: CB30
Description: Movable tray shift motor abnormality: The movable tray shift motor is not rotating or the movable tray is not moving normally. [MJ-1101] Movable tray shift motor abnormality: The movable tray shift motor or the movable tray does not work properly. [MJ-1032] Movable tray shift motor abnormality: The movable tray shift motor or the movable tray does not work properly. [MJ-1033]
Causes: MJ-1101 Movable tray shift motor (M7) Movable tray position A, B, and C sensors (S13, S14, and S15) Finisher controller PC board
MJ-1106 Movable tray shift motor (M7) Movable tray position A, B, and C sensors (S13, S14, and S15) Finisher controller PC board
MJ-1106 Movable tray shift motor (M7) Movable tray position A, B, and C sensors (S13, S14, and S15) Finisher controller PC board
Remedy: MJ-1101 Movable tray If there is mechanical problem when the movable tray is moved, fix the mechanism. Movable tray shift motor (M7) Check the connectors and harnesses between the movable tray shift motor (M7) and the finisher control PC board (CN8). Movable tray position A, B, and C sensors (S13, S14, and S15) • Connector check • Sensor check
MJ-1106 Movable tray If there is mechanical problem when the movable tray is moved, fix the mechanism. Movable tray shift motor (M12) Check the connectors and harnesses between the movable tray shift motor (M12) and the finisher control PC board (CN16). Movable tray position A, B, and C sensors (S13, S14, and S15) • Connector check • Sensor check
MJ-1032 Movable tray shift motor (M1) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the moto Movable tray lower limit sensor (S14) abnormality Measure the voltage on TP17 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity among the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN4, CN10) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensors and connectors, exchange the finisher control PC board (FIN). Stack top detection solenoid (SOL1) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the solenoid. Stack top detection sensor-1 (S1) abnormality Measure the voltage on TP11 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Stack top detection sensor-2 (S2) abnormality Measure the voltage on TP20 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Finisher control PC board (FIN): CN3) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the solenoid, sensors and connector, exchange the finisher control PC board (FIN).
MJ-1033 Movable tray shift motor (M5) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Movable tray shift motor clock sensor (S15) abnormality Measure the voltage on pin CN7.3 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Movable tray upper limit sensor (S16) abnormality Measure the voltage on TP35 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Movable tray lower limit sensor (S17) abnormality Measure the voltage on TP28 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Movable tray middle sensor (S18) abnormality Measure the voltage on TP29 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity among the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN11, CN7, CN9, CN8) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensors and connectors, exchange the finisher control PC board (FIN).
MJ-1106 Movable tray If there is mechanical problem when the movable tray is moved, fix the mechanism. Movable tray shift motor (M12) Check the connectors and harnesses between the movable tray shift motor (M12) and the finisher control PC board (CN16). Movable tray position A, B, and C sensors (S13, S14, and S15) • Connector check • Sensor check
MJ-1032 Movable tray shift motor (M1) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the moto Movable tray lower limit sensor (S14) abnormality Measure the voltage on TP17 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity among the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN4, CN10) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensors and connectors, exchange the finisher control PC board (FIN). Stack top detection solenoid (SOL1) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the solenoid. Stack top detection sensor-1 (S1) abnormality Measure the voltage on TP11 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Stack top detection sensor-2 (S2) abnormality Measure the voltage on TP20 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Finisher control PC board (FIN): CN3) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the solenoid, sensors and connector, exchange the finisher control PC board (FIN).
MJ-1033 Movable tray shift motor (M5) abnormality Check if the electrical continuity of the coil is normal. If electricity is not conducted, replace the motor. Movable tray shift motor clock sensor (S15) abnormality Measure the voltage on pin CN7.3 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Movable tray upper limit sensor (S16) abnormality Measure the voltage on TP35 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Movable tray lower limit sensor (S17) abnormality Measure the voltage on TP28 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Movable tray middle sensor (S18) abnormality Measure the voltage on TP29 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity among the connector terminals is normal. If electricity is not conducted, replace the connectors. (Finisher control PC board (FIN): CN11, CN7, CN9, CN8) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the motor, sensors and connectors, exchange the finisher control PC board (FIN).