Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E010 — Toshiba e-Studio 506SE

Code: E010

Description: Jam not reaching the exit sensor: The paper which has passed through the fuser unit does not reach the exit sensor.
Causes: Exit sensor LGC board Registration roller clutch Registration roller
Remedy: 1 Open the Automatic duplexing unit. Is there any paper on the transport path? Yes Remove the paper. No 2 2 Is the exit sensor working? (Perform the input check in the test mode: 03- [FAX]ON/[9]/[B]) Yes 3 No • Check if the connector of the exit sensor is disconnected. • Check if the connector CN309 on the LGC board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. • Replace the exit sensor • Replace the LGC board 3 Is the registration roller clutch working? (Perform the output check in the test mode: 03-108/ 158) Yes 4 No • Check if the connector of the registration roller clutch is disconnected. • Check if the connector CN315 on the LGC board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. • Replace the registration roller clutch. • Replace the LGC board. 4 Registration roller • Check the registration roller. Replace it if it is worn out.

← Xem tất cả mã lỗi Toshiba e-Studio 506SE

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie