Code: C270
Description: Carriage home position sensor not turning OFF within a specified period of time: The carriages do not shift from their home position within a specified period of time.
Remedy: Are the carriages slightly moved to the feeding direction? Are the carriages staying at a position other than home position? ll → YES → 1) Check if the conductor pattern on the SLG board is short circuited or open circuited. 2) Replace the SLG board. NO 1) Check if the connector pin is disconnected and the harness is short circuited or open circuited. 2) Check if the conductor pattern on the SLG board is short circuited or open circuited. 3) Replace the SLG board.