Code: C26

Description: Peak detection error
Remedy: Does the exposure lamp light? Yes • Check the connectors on the CCD and SLG boards for disconnection. • Check the shading plate on the rear of the original scale for dirt. • Check the CCD board for breaks and short-circuits. • Check the SLG board for breaks and short-circuits. • Replace the lens unit. • Replace the SLG board. No • Check the lamp connectors for disconnection. • Check the thermostat to see if it has blown. • Check electrical continuity of the lamp. • Check SLG board connector pins J9-22, 23, 24, 25 and 26 for disconnection and the harness for breaks and short-circuits. • Check the SLG board for breaks and short-circuits. • Replace the SLG board. • Replace the lamp regulator