Code: C48
Description: IGBT high temperature
Remedy: 1. Check the operation of the IH fan Check if the IH fan is rotating normally. (Is the connector securely connected?) 2. Check the IH control board (1) Check if the IGBT or IGBT radiation plate are normal. (Is the radiation plate securely attached?) (2) Check if the conductor pattern on the board is short- or open-circuited. (3) Replace the IH control board. 3. Clear the status counter Change the values “12”, “14”, “15” or “18” of the status counter (08-400) to “0”. * The status counter value is as follows in the following cases. Change them to "0" respectively. • The error occurred before the temperature of the fuser roller reaches 40°C: "12" • The error occurred before the temperature of the fuser roller reaches 150°C: "15" • The error occurred before the machine has become ready: "14" • The error occurred when the machine is in the ready state: "18"