Description: LCF end fence motor abnormality: The LCF end fence motor is not rotating or the LCF end fence is not moving normally. (the case that paper can be fed from any drawer except the LCF)
Remedy: Is the LCF end fence motor working? (Perform the output check: 03-256) NO 1. Check if the connector of the LCF end fence motor is disconnected. 2. Check if the connector CN507 on the PFC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open circuited. 4. Check if the conductor patterns on the PFC board is short circuited or open circuited. 5. Replace the LCF end fence motor. 6. Replace the PFC board. YES Are the LCF end fence home/stop position sensors working? (Perform the input check: 03-[Copy ON]/[9]/[E], [Scan ON /[1]/[E]) NO 1. Check if the connectors of the sensors are disconnected. 2. Check if the connector CN507 on the LGC board is disconnected. 3. Check if the slit reaches the sensors. 4. Check if the connector pins are disconnected or the harnesses are open circuited. 5. Check if the conductor patterns on the PFC board is short circuited or open circuited. 6. Replace the sensors. 7. Replace the PFC board. YES 1. Check if the conductor pattern on the PFC board is short circuited or open circuited. 2. Replace the PFC board.