Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CF10 — Toshiba e-Studio 5520c

Code: CF10

Description: Communication module SRAM reading failure.
Remedy: MJ-1103/1104 1. Is the error recovered when the power of the equipment is turned OFF and then back ON? 2. Check if the MJ-1103/1104 is set as the specified finisher on the equipment. 3. Check if the harness connecting the converter PC board and the finisher controller PC board is disconnected or open circuited. 4. Check if the conductor pattern on the converter PC board is open circuited or short circuited. 5. Check if the conductor pattern on the finisher controller PC board is open circuited or short circuited. 6. Replace the converter PC board. 7. Replace the finisher control PC board. MJ-1103/1104 (When MJ-6102 is installed) 1. Is the error recovered when the power of the equipment is turned OFF and then back ON? 2. Check if the MJ-1103/1104 is set as the specified finisher on the equipment. 3. Check if the harness connecting the converter PC board and the finisher controller PC board is disconnected or open circuited. 4. Check if the harness connecting the hole punch control PC board and the finisher control PC board is disconnected or open circuited. 5. Check if the conductor pattern on the converter PC board is open circuited or short circuited. 6. Check if the conductor pattern on the finisher controller PC board is open circuited or short circuited. 7. Check if the conductor pattern on the hole punch control PC board is open circuited or short circuited. 8. Replace the converter PC board. 9. Replace the finisher control PC board. 10.Replace the hole punch control PC board.

← Xem tất cả mã lỗi Toshiba e-Studio 5520c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie