Remedy: (1) Turn the power OFF and start up the Setting Mode (08). (2) When “SRAM ERROR DOES IT INITIALIZE” is displayed on the LCD, check the destination and then press the [START] button. If the destination is not correct, key in the correct one and then press the [START] button. (3) After the confirmation message is displayed on the LCD, press the [INTERRUPT] button (to initialize the SRAM). (4) Perform the panel calibration (08-692). (5) Enter the serial number (08-995). Be sure that the serial number is the same as that on the identification label attached on the rear cover of the equipment. (6) Initialize the NIC information (08-693). (7) Turn the power OFF and then start up with the Adjustment mode (05). (8) Perform “Data transfer of characteristic value of scanner” (05-364). (9) Perform “Automatic gamma adjustment” <PRC> (05-1642) (using [4] [FAX] test pattern). (10) Perform “Automatic gamma adjustment” <PRT (600dpi)> (05-1008) (using [70] [FAX] test pattern). (11) Perform “Automatic gamma adjustment” <PRT (1200dpi)> (05-1009) (using [230] [FAX] test pattern). (12) Turn the power OFF and then back ON. If the error is not recovered, replace the SRAM on the SYS board.