Mã lỗi C022 — Toshiba e-Studio 5530c

Code: C022

Description: Developer unit mixer motor-YMC locking error: The developer unit mixer motor-YMC is not rotating normally
Remedy: (1) Pull out the EPU tray and perform the output check (03-115) to check if the 3 outputs of the YMCdeveloper unit mixer are rotating normally. When it is not rotating (2) Is the connector of the YMC-developer unit mixer motor connected securely? (3) Check if the harness or connector of the YMC-drum motor is disconnected or open-circuited. (4) Check if the YMC-developer unit mixer motor is abnormal. (5) Check if the drive gear array has any abnormality such as breakage. When it is rotating (6) Check if developer material is excessively supplied to each YMC-developer unit. (7) Check if the drive gear array of each YMC-developer unit has any abnormality such as breakage.

← Xem tất cả mã lỗi Toshiba e-Studio 5530c