Mã lỗi C412 — Toshiba e-Studio 5530c

Code: C412

Description: Thermistor/heater lamp abnormality at power-ON: Thermistor abnormality is detected at power-ON or the fuser belt temperature does not rise within a specified period of time after power-ON.
Remedy: 1.Check the power voltage (1) Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) 2.Check the error detection history (1) Check the error detection history of each temperature detecting element when the error occurred. If any of the elements detects an abnormal temperature, check step 3. 08-1902: Fuser belt center thermopile temperature 08-1903: Fuser belt side thermopile temperature 08-1904: Fuser belt edge thermistor temperature 08-1905: Pressure roller center thermistor temperature 08-4545: Pressure roller rear thermistor temperature 3.Check the thermopiles (1) Check if the fuser belt center and side thermopiles (front, rear) are installed properly. (2) Check if the harnesses of the fuser belt center and side thermopiles (front, rear) are open circuited. 4. Check the IH board, IH coil and the fuser unit (1) Is the fuser unit installed correctly? (2) heck if foreign matter or paper in the fuser unit is plugging up the monitoring opening of the fuser belt thermopile. (3) Check if the opening of the fuser belt thermopile of the equipment is plugged up. (4) Is the IH coil open circuited? (Check if power is supplied to the IH coil.) (5) Check if the connector of the IH coil is disconnected. (6) Check if the thermostat is broken. (7) Check if any of the connectors (AC input connector and LGC I/F connector CN462) on the IH board is disconnected. (8) Is the IH board broken?. • Replace the IH board. 5. Check the LGC board (1) Check if the connectors CN333 and CN345 are disconnected. (2) Check if the conductor pattern on the LGC board is short circuited or open circuited. (3) Replace the LGC board. 6. Clear the status counter After repairing the matter which caused the error [C411/C412], perform the following: (1) Turn ON the power while [0] and [8] are pressed simultaneously. (2) Key in “400”, then press [START]. (3) Change the current status counter value “1” or “2” to “0”, then press [ENTER] or [INTERRUPT] (to cancel [C411/C412]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.

← Xem tất cả mã lỗi Toshiba e-Studio 5530c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie